Healthcare Ceiling Tile 608
Healthcare Ceiling Tile 608 is a fiberglass ceiling panel designed for interiors with demanding moisture, maintenance and acoustic requirements. The UET product handbook lists square-edge, tegular-edge and C362 concealed-grid options, with front-and-back treatment described for waterproof and dustproof performance. Confirm the selected configuration, applicable hygiene requirements and current technical documents before specifying or ordering.

Healthcare Ceiling Tile 608 Specifications
| Edge detail | Thickness | Panel sizes listed in handbook | NRC | Sound Insulation Class | Light reflectance |
| Square edge | 15 mm | 600 × 600 mm; 600 × 1200 mm | 0.90 | 35 | 0.88 |
| Square edge | 20 mm | 600 × 600 mm; 600 × 1200 mm; 1200 × 1200 mm | 0.95 | 37 | 0.88 |
| Tegular edge | 15 mm | 600 × 600 mm; 600 × 1200 mm | 0.90 | 35 | 0.88 |
| Tegular edge | 20 mm | 600 × 600 mm; 600 × 1200 mm; 1200 × 1200 mm | 0.95 | 37 | 0.88 |
| C362 concealed-grid edge | 20 mm | 600 × 600 mm; 600 × 1200 mm; 1200 × 1200 mm | 0.95 | 37 | 0.88 |
| Specification | Healthcare Ceiling Tile 608 |
| Product code | 608 |
| Concealed-grid option | C362 |
| Panel material | Dry high-density glass fiber |
| Surface coating | Natural stone powder |
| Front and back treatment | Described in the handbook as waterproof and dustproof treatment; confirm current product documentation |
| Fire classification | A2 |
| Moisture resistance class | RH99 |
Project Applications to Consider
The UET product handbook lists the following recommended settings for Healthcare Ceiling Tile 608. Confirm the hygiene, moisture, cleaning, acoustic and installation requirements for the selected project before choosing a configuration.

Hospitals
Coordinate the selected ceiling configuration with the project’s hygiene, maintenance, acoustic and service-access requirements.

Emergency Rooms
Confirm the required cleaning, moisture, acoustic and installation conditions for the selected ceiling system.

Observation Rooms
Review the room’s maintenance plan, acoustic objectives and ceiling layout against current product documents.

Labs
Check the selected panel configuration against the laboratory’s cleaning, moisture, service-access and project requirements.

Kitchens & Restrooms
Confirm the expected moisture, cleaning and maintenance conditions before selecting the ceiling configuration.

Food Processing Zones
Review the project’s hygiene, cleaning, moisture and installation requirements with the current product documentation.

Clean Workshops
Coordinate the ceiling layout, cleaning plan, service access and selected panel details with the project specification.

Computer Rooms
Consider the room’s maintenance, acoustic and service-access requirements when selecting the ceiling configuration.
Installation & Compatibility
Before specifying Healthcare Ceiling Tile 608, confirm the available panel size, thickness and edge detail for the selected configuration. Check compatibility with the suspension grid, perimeter details, service access, cleaning plan and installation conditions against the project drawings and current technical documents. The C362 concealed-grid option should not be assumed to use the same installation detail as square-edge or tegular-edge panels.
Product Documents & Inquiry
For a Healthcare Ceiling Tile 608 inquiry, share the required size, thickness, edge detail, estimated quantity, project location and any ceiling drawings or hygiene, cleaning or specification requirements. Contact UET Ceilings to confirm current availability, samples, technical documents and ordering details.